Skip to main content

ConceptWall 50 Transom Transom

Technical information

Performance

Energy

Thermal insulation - Ucw
0.56 W/m²K

Comfort

Air tightness
AE 1200 (1200Pa)
Water tightness
RE1200 (1200 Pa)
Wind load resistance
Class A5 (2000Pa)
Acoustics - Rw(C;Ctr)
47(-2;-5) dB

Safety

Burglar resistance
RC2 - RC3
Impact resistance
I5 - E5
Performance and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative for more specific information.

Properties

Max. dimensions & weight

Min. height of vent
600 mm
Min. width of vent
450 mm
Max. weight of vent
180 kg
Min. intertia mullion - Ix
74 cm4
Max. intertia transom - Ix
937 cm4
Min. intertia transom - Iy (glass load)
23 cm4
Max. intertia transom - Iy (glass load)
68 cm4

Sightlines

Min. width T-profile
50 mm
Min. visible width (interior view)
50 mm
Min. visible width (exterior view)
50 mm
Min. depth mullion
83.5 mm
Max. depth mullion
230.5 mm
Min. depth transom
83.5 mm

Glazing

Rebate height
20 mm
Glazing method
Dry glazing - Siliconized glazing - Pressure plate glazing
Min. glass thickness - frame/element
8 mm
Max. glass thickness - frame/element
64 mm