Skip to main content

ConceptWall 50 Structural Clamped

Technical information

Performance

Energy

Thermal insulation - Utj
5.7 W/m²K

Comfort

Air tightness
AE 1200 (1200Pa)
Water tightness
RE1200 (1200 Pa)
Wind load resistance
E2400 (2400Pa)
Acoustics - Rw(C;Ctr)
47(-2;-6) dB

Safety

Impact resistance
I5 - E5
Performance and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative for more specific information.

Properties

Max. dimensions & weight

Min. height of vent
600 mm
Min. width of vent
450 mm
Max. weight of vent
180 kg
Min. intertia mullion - Ix
13.5 cm4
Max. intertia transom - Ix
534.7 cm4
Min. intertia transom - Iy (glass load)
7.9 cm4
Max. intertia transom - Iy (glass load)
59 cm4

Sightlines

Min. width T-profile
50 mm
Min. visible width (interior view)
50 mm
Min. visible width (exterior view)
50 mm
Min. depth mullion
41.5 mm
Max. depth mullion
300 mm
Min. depth transom
5 mm

Glazing

Rebate height
20 mm
Glazing method
Dry glazing - External glazing - Structural clamped glazing
Min. glass thickness - frame/element
27 mm
Max. glass thickness - frame/element
63 mm