ConceptWall 50 Fireproof
Technical informationPerformance
Energy
- Thermal insulation - Uf
- 0.8 W/m²K
Comfort
- Air tightness
- AE 1200 (1200Pa)
- Water tightness
- Class E1500 (1500Pa)
Safety
- Impact resistance
- I5 - E5
- Fire resistance
- EI 30 - EI 60 - EW 30
Properties
Max. dimensions & weight
- Min. intertia mullion - Ix
- 125 cm4
- Max. intertia mullion - Ix
- 461 cm4
- Min. intertia transom - Ix
- 74 cm4
- Max. intertia transom - Ix
- 219 cm4
- Min. intertia transom - Iy (glass load)
- 24 cm4
- Max. intertia transom - Iy (glass load)
- 41 cm4
Sightlines
- Min. visible width (interior view)
- 50 mm
- Min. visible width (exterior view)
- 50 mm
- Min. depth mullion
- 83 mm
- Max. depth mullion
- 167 mm
- Min. depth transom
- 83 mm
- Max. depth transom
- 125 mm
- Min. wall inclination - standard
- 10 degrees
- Max. wall inclination - standard
- 10 degrees
Glazing
- Rebate height
- 20 mm
- Glazing method
- Dry glazing - External glazing - Pressure plate glazing
- Min. glass thickness - frame/element
- 34 mm
- Max. glass thickness - frame/element
- 78 mm